  • Case Studies // DD - Boiler Design & Diagnostics

    The boiler manufacturer blamed poor water treatment, pointing to the presence of a thin scale detected on the inside surface of the tube within the zone of the failures. A new water treatment chemical supplier was engaged but despite an intense focus on optimizing water chemistry over an additional 12-month period the problem persisted.Get Price

  • Failure analysis of ruptured tubes from refinery steam boiler

    Failure analysis of ruptured tubes from refinery steam boiler. The other appeared to have failed due to an unusual form of hydrogen attack. Failures in …Get Price

  • Hydrogen embrittlement in power plant steels | SpringerLink

    Islam M 1993 An unusual case of hydrogen induced failure in a refinery boiler tube.Handbook of case histories in failure analysis (ed.) Khlefa A Easaklul (Materials Park, OH: ASM Int.) vol. 2, pp 145–147. Google Scholar Jones W F 1993 Hydrogen induced cracking of …Get Price

  • Handbook of Case Histories in Failure Analysis, Volume 2

    Dished Ends During Storage 135-137 Pipes and Pipelines Acidic Pitting in Waterwall Tubing 138-140 Alkaline Type Boiler Tube Failures Induced by Phosphate Water Treatment 141-144 An Unusual Case of Hydrogen-Induced Failure in a Refinery Boiler Tube 145-147 Caustic Gouging and Caustic-Induced Stress-Corrosion Cracking of Superheater TubeGet Price

  • Failures of boilers and pressure vessels: Their causes and

    Apr 01, 1973 · The UK boiler failures reviewed by Eyers & Nisbett (1964/5) cover explosions of all types, from complete rupture of a shell or boiler drum to failure of an individual tube. Figure 1 shows the statistics from 1860 to 1960, indicating a generally declining rate of failure and a substantial fall in the number of persons killed and injured by Get Price

  • David LÓPEZ | Senior Researcher | Dr. | Instituto Mexicano

    Unusual Refinery Boiler Tube Failures Due to Corrosion by Sulfuric Acid Induced by Steam Leaks. Article. Full-text available. David López López. Adriana Moreno. View. Network. Cited. View All.Get Price

  • Unusual Refinery Boiler Tube Failures Due to Corrosion by

    Mar 22, 1998 · ABSTRACT. Corrosion by sulfuric acid in boilers is a low probability event because gas temperature and metal temperature of boiler tubes are high enough to avoid the condensation of sulfuric acid from flue gases. This degradation mechanism is frequently considered as an important cause of air preheaters materials degradation, where flue gases …Get Price

  • (PDF) Unusual Refinery Boiler Tube Failures Due to

    In the present work, failure of generator tubes of two small oil-fired subcritical boilers where sulfuric acid corrosion was the root cause is reported. The sulfuric acid condensation was related to small water-steam leaks which gave place, as a first stage, to a localized corrosion phenomenon generating small holes.Get Price

  • Boiler tube failures: Case histories of steam blanketing

    Aug 01, 1994 · Abstract. Case histories in which boiler tube failures resulted from a combination of steam blanketing and underdeposit corrosion are reviewed. Steam blanketing originates from inadequate circulation and commonly occurs in horizontal or sloped boiler tube circuits in …Get Price

  • (47bq) A Functional System Approach to Criticality

    Mar 31, 2014 · Case 2: Refinery boiler feed pretreatment RO system. Situation. A boiler feed water pretreatment system was due for an expansion and had undergone several design reviews, two HAZOP reviews, and several construction reviews. However, given the importance of this system within the refinery operation, asGet Price

  • Application Data | Holz Rubber

    Uncontrolled Movements Causes Failure. Application: Condensate water piping for the boiler system used in the pulp and paper industry for heat and energy generation. Problem: After 6-1/2 years in operation, an Expansion Joint failed due to the bolts repeatedly rubbing the expansion joint's body.The anchor points failed and allowed the pipe flanges to move laterally from side …Get Price

  • Unusual refinery boiler tube failures due to corrosion by

    Dec 31, 1998 · @article{osti_352627, title = {Unusual refinery boiler tube failures due to corrosion by sulfuric acid induced by steam leaks}, author = {Lopez-Lopez, D and Wong-Moreno, A}, abstractNote = {Corrosion by sulfuric acid in boilers is a low probability event because gas temperature and metal temperature of boiler tubes are high enough to avoid the condensation …Get Price

  • Six case histories of pressure vessel failures - ScienceDirect

    Sep 01, 1996 · The boiler was fully pressurized on 1 April and passed by the surveyors, except for a number of tube defects. The boiler was pressurized again on 22 April to check that the repairs, which were not associated with the drum, were satisfactory. The failure of the drum occurred during the final pressure test on 6 May.Get Price

  • Crude column overhead corrosion problems caused by

    Unusual refinery boiler tube failures due to corrosion by sulfuric acid induced by steam leaks Conference Lopez-Lopez, D ; Wong-Moreno, A Corrosion by sulfuric acid in boilers is a low probability event because gas temperature and metal temperature of boiler tubes are high enough to avoid the condensation of sulfuric acid from flue gases.Get Price

  • Handbook of Case Histories in Failure Analysis, Vol. 2

    Fatigue Failure of Steering Arms Due to Forging Defects Alkaline Type Boiler Tube Failures Induced by Phosphate Water Treatment An Unusual Case of Hydrogen-Induced Failure in a Refinery Boiler Tube Caustic Gouging and Caustic-Induced Stress-Corrosion Cracking of Superheater TubeGet Price

  • Acid And Alkali Corrosion boiler - boulepate-cave.fr

    Dec 31, 1998 · @article{osti_352627, title = {Unusual refinery boiler tube failures due to corrosion by sulfuric acid induced by steam leaks}, author = {Lopez-Lopez, D and Wong-Moreno, A}, abstractNote = {Corrosion by sulfuric acid in boilers is a low probability event because gas temperature and metal temperature of boiler tubes are high Get Price

  • Adriana Wong-Moreno | Instituto Mexicano del Petroleo

    Internal corrosion and circumferential cracking due to a corrosion fatigue process are some of the most common failure causes of waterwall boiler tubes. The case study reported in this paper considers the failure of waterwall tubes of a small subcritical refinery boiler due to a combination of both processes.Get Price

  • (PDF) Boiler Tubes Failures: A Compendium of Case …

    R.B. Dooley and W.P. McNaughton, Boiler Tube Failures: Theory and Practice, vol. 1–3, TR-105261-V1 to V3, EPRI, 1996 Metallurgical Failures in Fossil Fired Boilers Jan 1993Get Price

  • Reformer Tube Failure I | Fracture | Boiler

    Lessons Learned From an Unusual Hydrogen Reformer Furnace. Failure Mike Rogers, Syncrude Canada Ltd. Fort McMurray Alberta Canada. On January 30,2005 a high-energy pressure impulse occurred within several radiant tubes of a steam/ methane reformer furnace during startup after a partial shutdown. This impulse caused the simultaneous rupture of 5 tubes with sufficient …Get Price

  • Some common corrosion mechanisms leading to boiler …

    Oct 01, 1996 · Unusual refinery boiler tube failures due to corrosion by sulfuric acid induced by steam leaks Conference Lopez-Lopez, D ; Wong-Moreno, A Corrosion by sulfuric acid in boilers is a low probability event because gas temperature and metal temperature of boiler tubes are high enough to avoid the condensation of sulfuric acid from flue gases.Get Price

  • Metallurgical Failure Investigation of an In-Service

    The consequence of service failure can be tragic and expensive. There are many cases of engineering disasters resulting in loss of life and property. For oil refinery and boiler components utmost attention is a must to ensure that such incidents do not take place. Life assessment exercise performed at regular intervals is a means to ensure Get Price

  • DESIGNING A ROBUST WASTE HEAT BOILER

    exists, such as damage or failure of tubes (Figure F) and tube collapse (Figure G), which may both be due to inadequate boiler water quality, loss of water level in the boiler, or excessive temperature or mass flux. The control of water level may be a contributing factor to tube failures.Get Price

  • Boiler failure modes — $69 boiler repair diagnostic

    Boilers Tube Failure Analysis 2018 Rev 0 - Free download as Powerpoint Presentation (.ppt / .pptx), PDF File (.pdf), Text File (.txt) or view presentation slides online. Boiler tube failure Analysis technique use metallurgical and chemical analysis to study failure modes. For a long period of time researchers have given great interest in boiler Get Price

  • Gas Steam Boiler Failure Analysis

    Unusual refinery boiler tube failures due to corrosion by :D Lopez-Lopez · 1998 — In this paper, the failure analysis of generator tubes (similar to the of flue gases containing SO{sub 3} with water-steam spray coming from Get A QuoteGet Price

  • Acid And Alkali Corrosion boiler - boulepate-cave.fr

    Unusual refinery boiler tube failures due to corrosion by Preventing steam condensate corrosion in industrial boilers and steam generating systems is important for several reasons.Get Price

  • 98720 UNUSUAL REFINERY BOILER TUBE FAILURES DUE TO

    98720 unusual refinery boiler tube failures due to corrosion by sulfuric acid induced by steam leaksGet Price

  • Blog – Providing complete water consulting services for

    Apr 30, 2021 · The boiler had operated for at least 20 years and had never had a tube failure. When I arrived on the scene to survey the situation, the boiler operator told me the boiler had three tube failures caused by oxygen pitting in the last 3 years. The unusual thing was it was the same tube that was failing.Get Price

  • OSHA Technical Manual (OTM) - Section IV: Chapter 2

    Boilers consist of a number of tubes that carry the water-steam mixture through the furnace for maximum heat transfer. These tubes run between steam-distribution drums at the top of the boiler and water-collecting drums at the bottom of the boiler. Steam flows from the steam drum to the superheater before entering the steam distribution system.Get Price

  • (PDF) Failure of Oil-Fired Boiler Waterwall Tubes due to

    The present work is focused on the failure analysis of waterwall tubes of a refinery boiler. The boiler has the capacity for generating 55.6 kg/s of steam at 6 MPa and 485 0 C, and has six frontGet Price

  • Benchmarking boiler tube failures - Part 1 (Journal

    Oct 01, 2005 · Abstract. Boiler tube failures continue to be the leading cause of downtime for steam power plants. That should not be a surprise; a typical steam generator has miles of tubes that operate at high temperatures and pressures.Get Price

  • What is the key step to preventing a potential boiler

    An explosion can happen due to a sudden outburst or expansion of energy. Boilers can certainly explode. This is usually due to a build-up of pressure or mechanical failure due to the boiler deteriorating. Technology has significantly decreased the frequency of boiler explosions, making them a safer way to heat your homeGet Price

  • Instituto Mexicano del Petroleo | Laboratorio de Sistemas

    Internal corrosion and circumferential cracking due to a corrosion fatigue process are some of the most common failure causes of waterwall boiler tubes. The case study reported in this paper considers the failure of waterwall tubes of a small subcritical refinery boiler due to a combination of both processes.Get Price

  • Evaporator Failure Caused By Corrosion And Flow | NACE

    Mar 16, 2008 · Unusual Refinery Boiler Tube Failures Due to Corrosion by Sulfuric Acid Induced by Steam Leaks. CORR98. A New Understanding For The Mechanism Of Caustic Gouging Of Boiler Tubes Reaction. CORR07. The Metal Doesn't Lie - …Get Price

  • Investigations of the Failure in Boilers Economizer Tubes

    Investigations of the Failure in Boilers Economizer Tubes Used in Power Plants. Journal of Materials Engineering and Performance, 2013. Roozbeh Siavash.Get Price

  • David LÓPEZ | Senior Researcher | Dr. | Instituto Mexicano

    Unusual Refinery Boiler Tube Failures Due to Corrosion by Sulfuric Acid Induced by Steam Leaks. Article. Full-text available. David López López. Adriana Moreno. View. Network. Cited. View All.Get Price

  • Transportation Component Failures Aircraft-Aerospace

    Alkaline Type Boiler Tube Failures Induced by Phosphate Water Treatment p. 141 An Unusual Case of Hydrogen-Induced Failure in a Refinery Boiler Tube p. 145 Caustic Gouging and Caustic-Induced Stress-Corrosion Cracking of Superheater Tube U-Bends p. 148 Caustic-Induced Stress-Corrosion Cracking of a Flue Gas Expansion Joint p. 153Get Price

Hey, let me help you!